IBM DU3 2104 Hardware Technical Information

Expandable storage plus
Hide thumbs Also See for DU3 2104:

Advertisement

Quick Links

Expandable Storage Plus
2104 Models DU3 and TU3
Hardware Technical Information
SA33-3309-00

Advertisement

Table of Contents
loading

Summary of Contents for IBM DU3 2104

  • Page 1 Expandable Storage Plus 2104 Models DU3 and TU3 Hardware Technical Information SA33-3309-00...
  • Page 3 Expandable Storage Plus 2104 Models DU3 and TU3 Hardware Technical Information SA33-3309-00...
  • Page 4 First Edition (October 2000) The following paragraph does not apply to any country where such provisions are inconsistent with local law: THIS PUBLICATION IS PRINTED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Page 5: Table Of Contents

    Contents About This Book . Related Publications Trademarks . Chapter 1. Introduction . 2104 Model DU3 2104 Model TU3. SCSI Disk Drive Modules . SCSI Interface Cards . Fan-and-Power-Supply Assemblies Switch Card . SCSI Bus Bridge Card . . 10 SCSI Bus Configurations .
  • Page 6 Mainline-Power Connectors . 26 2104 Models DU3 and TU3 Hardware Technical Information...
  • Page 7: About This Book

    Expandable Storage Plus : 2104 Models DU3 and TU3 Service Guide, GY33-0198 Trademarks The following items are trademarks of International Business Machines Corporation in the United States, or other countries, or both: v AIX v IBM v RS/6000 1. American National Standards Institute.
  • Page 8 2104 Models DU3 and TU3 Hardware Technical Information...
  • Page 9: Chapter 1. Introduction

    Chapter 1. Introduction This section describes the 2104 Models DU3 and TU3 and their components. Figure 1. 2104 Model TU3 (on the Left) and 2104 Model DU3 (on the Right)
  • Page 10: 2104 Model Du3

    The 2104 Model DU3 is a rack-mounted SCSI disk enclosure that can be attached to server ™ ™ any RS/6000 or IBM pSeries computer that provides support for any of the Small Computer System Interface (SCSI) adapters listed in “SCSI Adapters and Cables” on page 25.
  • Page 11 On the back of the backplane are connectors for two fan-and-power-supply assemblies 3 , two SCSI interface cards 4 , and a switch card 5 . The 2104 Model DU3 has either two fan-and-power-supply assemblies or one fan-and-power-supply assembly and one fan assembly. Either option provides all the necessary power and cooling for the 2104 Model DU3.
  • Page 12: 2104 Model Tu3

    The 2104 Model TU3 is a deskside SCSI disk enclosure that can be attached to any server RS/6000 or IBM pSeries computer that provides support for any of the Small Computer System Interface (SCSI) adapters listed in “SCSI Adapters and Cables” on page 25.
  • Page 13 The 2104 Model TU3 can have either two fan-and-power-supply assemblies or one fan-and-power-supply assembly and one fan assembly. Either option provides all the necessary power and cooling for the 2104 Model TU3. The SCSI interface cards are used to connect host machines to the 2104 Model TU3. These cards contain logic that provides information about what is happening in the 2104 Model TU3, and controls the operation of the subsystem.
  • Page 14: Scsi Disk Drive Modules

    Nominal capacity Nominal Speed in RPM Feature Number 9.1 GB 10000 6109 18.2 GB 10000 6118 36.4 GB 10000 6136 Please obtain the latest product information from the following IBM Web address: www.ibm.com/storage 2104 Models DU3 and TU3 Hardware Technical Information...
  • Page 15: Scsi Interface Cards

    SCSI Interface Cards Attached to the back of the backplane in a fully configured 2104 Model DU3 or 2104 Model TU3 are two SCSI interface cards. Both cards can be used to connect host machines to the 2104 disk enclosure. A SCSI interface card provides the following functions: v Supports SCSI Enclosure Services at the SCSI node at address 15 on the external SCSI bus...
  • Page 16: Fan-And-Power-Supply Assemblies

    Fan-and-Power-Supply Assemblies Attached to the back of the backplane in a fully configured 2104 Model DU3 or 2104 Model TU3 are two fan-and-power-supply assemblies. Each fan-and-power-supply assembly provides enough power for the 2104, so it is possible for there to be just one fan-and-power-supply assembly in a 2104. The second fan-and-power-supply assembly is replaced by a fan assembly.
  • Page 17: Switch Card

    Switch Card Attached to the back of the backplane in a fully configured 2104 Model DU3 or 2104 Model TU3, the switch card contains switches that control some of the functions of the 2104. Switches that are accessible from the back of the 2104 are provided to indicate: v Whether power to the 2104 is turned on or off automatically when the host computer is switched on or off v Whether the disk drive modules are started automatically when power to the 2104 is...
  • Page 18: Scsi Bus Bridge Card

    SCSI Bus Bridge Card Located centrally in the front of a 2104 Model DU3 or 2104 Model TU3, the SCSI bus bridge card controls the SCSI bus configuration of the 2104. It assigns the disk drive modules to a SCSI bus, in accordance with the setting of the SCSI bus split switch on the switch card.
  • Page 19 Host bus adapter (HBA) Host bus adapter (HBA) ID:5 or 6 ID:6 or 5 Terminator Terminator Repeater Repeater SCSI SCSI interface interface Enclosure Enclosure card card service service processor processor 0 1 2 3 4 X X 8 9 10 11 12 13 14 Terminators Terminator Terminator...
  • Page 20 Host bus adapter (HBA) Host bus adapter (HBA) ID:7 ID:7 Terminator Terminator Repeater Repeater SCSI SCSI interface interface Enclosure Enclosure card card service service processor processor 0 1 2 3 4 5 6 8 9 10 11 12 13 14 Terminators Terminator Terminator...
  • Page 21: Chapter 2. Product Characteristics

    Chapter 2. Product Characteristics This section describes the physical characteristics of the 2104 Model DU3 and 2104 Model TU3, and their environmental and power requirements. Dimensions Model Height Width Depth Model DU3 128 mm 445 mm 552 mm max (5.0 in.) 3 EIA units (18 in.) (22 in.) Model TU3...
  • Page 22: Environment

    Environment Temperature and Humidity A 2104 has the following environmental limits: Air Temperature Relative Humidity Maximum Wet Bulb Operating 10°C to 40°C 8% to 80% 27°C (80°F) (50°F to 104°F) noncondensing Recommended 22°C operating point (72°F) Recommended 20°C to 25°C 40% to 50% operating range (68°F to 77°F)
  • Page 23: Heat Output, Airflow, And Cooling

    Heat Output, Airflow, and Cooling The maximum heat output of either model is 330 watts (1126 BTU/hr). Each 2104 requires an airflow of 1.1 m³ ( 40 cubic feet) per minute. When racks containing many 2104s are to be installed together, the following requirements must be met to ensure that the 2104s are adequately cooled: v The airflow is in at the front of the rack and out at the back.
  • Page 24: Electrical Power

    Electrical Power Electrical power is supplied to each 2104 by either one or two fan-and-power-supply assemblies. These fan-and-power-supply assemblies convert the input voltage to dc for distribution within the 2104. One fan-and-power-supply assembly provides enough power for a fully populated 2104. If two fan-and-power-supply assemblies are present in the 2104, each disk drive module receives power from both fan-and-power-supply assemblies.
  • Page 25: Power Factor

    Description Operating (100 disk ops per Two power supplies (100 second) disk ops per second) 100 VAC input 410 W 210 W each 240 VAC input 430 W 220 W each Power Factor Power factor correction is applied within the fan-and-power-supply assemblies of each 2104.
  • Page 26: Power Control

    Power Control Each fan-and-power-supply assembly in the 2104 has a DC On/Standby switch. The power to the 2104 is also controlled by the Power Control switch on the switch card. Power Sequencing The power sequencing of the disk drive modules in a 2104 is controlled by the settings of the Drive Auto-Start and Select Enclosure Services switches on the switch card.
  • Page 27: Safety Approvals

    Safety Approvals A 2104 Model DU3 or TU3 is certified to the following safety standards: v IEC 60950 (International Electrotechnical Commission) v EN 60950 (European Nom) v CSA950/UL1950 Binational (CSA Underwriters Laboratories’ binational ITE standard) Chapter 2. Product Characteristics...
  • Page 28: Electromagnetic Compatibility

    Electromagnetic Compatibility Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 29: Industry Canada Compliance Statement

    EG-Konformitätszeichen - CE - zu führen. Verantwortlich für die Konformitätserklärung nach Paragraph 5 des EMVG ist die: IBM Deutschland Informationssysteme GmbH, 70548 Stuttgart. Informationen in Hinsicht EMVG Paragraph 3 Abs. (2) : Das Gerät erfüllt die Schutzanforderungen nach EN 50082-1 und EN 55022 Klasse A.
  • Page 30: Taiwan Class A Compliance Statement

    Taiwan Class A Compliance Statement 2104 Models DU3 and TU3 Hardware Technical Information...
  • Page 31: Chapter 3. Physical Connections

    Chapter 3. Physical Connections Figure 7 shows the external connectors of the 2104 Model DU3. 1 are SCSI connectors and 2 are mainline power connectors. Figure 7. Back of a 2104 Model DU3 Showing External Connectors...
  • Page 32 Figure 8 shows the external connectors of the 2104 Model TU3. 1 are mainline power connectors and 2 are SCSI connectors. Figure 8. Back of a 2104 Model TU3 Showing External Connectors This section provides information about these connectors. 2104 Models DU3 and TU3 Hardware Technical Information...
  • Page 33: Scsi Adapters And Cables

    5 meters 9305 09L3303 3 meters 9303 09L3301 1 meter 9301 09L3299 6206 or 2493 3 meters 9313 09L3309 2415 3 meters 9323 09L3311 Please obtain the latest product information from the following IBM Web address: www.ibm.com/storage Chapter 3. Physical Connections...
  • Page 34 Mainline-Power Connectors Main AC Power Supply on a 2104 Model DU3 or 2104 Model TU3 A mainline-power connector is on each fan-and-power-supply assembly. The connector is a 10-amp, three-pin, polarized, IEC 320 input connector. See Figure 9, in which 1 is the ground connection, 2 is the neutral connection, and 3 is the live connection.
  • Page 36 Part Number: 07K8063 Printed in the U.S.A. SA33-3309-00...

This manual is also suitable for:

Tu3 2104