Warning Events
Warning events described in this section are reported via email notification. The
Attention LED will blink when warning events for the following occur:
v Media
v Fan
v Redundant power supply
An appropriate message will be posted on the Operator Control Panel and the Web
User Interface.
Table 8-3. Warning Events
30
SCSI: transport element full
31
SCSI: all slots empty
32
SCSI: invalid opcode
33
SCSI: invalid element address
34
SCSI: invalid field in CDB
35
SCSI: Invalid drive specified
36
SCSI: SEND DIAGNOSTIC command:
invalid test number
37
SCSI: invalid LUN
38
SCSI: parameter list length error
39
SCSI: parameter list error: invalid field
3A
SCSI: parameter list error: parameter not
supported
3B
SCSI: parameter value invalid
3C
SCSI: saving parameters not supported
3D
SCSI: invalid ID message
3E
SCSI: destination element full
3F
SCSI: source slot or drive empty
40
SCSI: wrong checksum
41
SCSI: command sequence error
42
SCSI: drive disabled
43
SCSI: I/O Station disabled
44
SCSI: flash image does not fit bootcode
45
SCSI: media removal prevented by drive
46
SCSI: media removal prevented by
library
47
SCSI: flash image does not fit personality Check the version of firmware used for the upgrade.
48
SCSI: drive type not supported in this
library
49
SCSI: incompatible magazine, magazine
not accessible
4A
SCSI: source not ready
4B
SCSI: destination source not ready
Refer to your host application documentation for problem
determination information.
Check your configuration settings.
Refer to your host application documentation for problem
determination information.
Check whether a version of firmware is available which
supports this drive type. For a list of supported drives, refer
to "Ultrium Tape Drives" on page 1-8.
Check your configuration settings.
Complete move process and retry operation.
8-11
Chapter 8. Error Codes