IBM TS3100 Setup, Operator, And Service Manual page 53

Ibm system storage tape library
Table of Contents

Advertisement

v If Auto Clean is enabled and a cleaning cartridge is not present, or if a cleaning
Figure 2-5. 4U library System Status screen showing media attention status
v The Power Supply Status will only appear if redundant power is being utilized
Figure 2-6. 4U library System Status screen showing a power supply failure
cartridge is present, but not in a reserved slot, Auto Clean status will show Chk
Media/Rsvd Slot? and Status will show a green check mark and the words
Media Attention.
with a 4U library, and the library was manufactured after March 14, 2008. If a
redundant power supply fails, the System Status screen will appear as shown in
Figure 2-6.
Note: If your library has -04 level redundant power supplies (see label on top of
power supply), it is normal for the one in "Standby" mode to turn its
"Green" LED off. You can test this power supply by pulling the power
connector from the other "Active" power supply. The power supply that
was in "Standby" mode will now become "Active", and its "Green" LED
should light. If it doesn't, replace it (refer to "Replacing a Power Supply"
on page 10-11).
If your library has -05 level redundant power supplies, the "Green" LED
will be ON on both power supplies. If both "Green" LEDs are not ON,
replace the failed power supply (refer to "Replacing a Power Supply" on
page 10-11).
Chapter 2. User Interfaces