17.6 Flow Chart

(Paper is transported to the first stopping
e-STUDIO281c/351c/451c
AUTOMATIC DUPLEXING UNIT (ADU)
Exit motor reverse
rotation ON
Specified time
has passed
ADU motor ON
ADU entrance
sensor ON?
Yes
Specified time has passed
position in ADU)
Trailing edge of
first paper turned
OFF the ADU exit
sensor?
Yes
ADU motor ON
ADU clutch ON
ADU exit sensor
check the arrival?
Yes
Specified time
has passed
A
No
ADU transport jam (E510)
No
ADU motor stopped
No
ADU transport jam (E520)