[G] Transfer belt cleaning blade
(1)
Take off the transfer belt cleaning unit
(
P.14-8 "[A] Transfer belt unit / Transfer
belt cleaning unit").
(2)
Remove 2 screws and take off the transfer
belt cleaning blade.
(3)
Remove the blade seals (both front and rear
sides).
Notes:
1. When the blade seals are being attached,
attach them on the position shown in the
figure at right (by slightly pushing it to the
direction of the arrow).
2. Be sure that the attached blade seals
come at the bottom side of the recovery
blade.
(4)
Remove the blade mylars (both front and
rear sides).
Notes:
1. When both the blade mylars are being
attached, attach them on the position
shown in the figure at right (by slightly
pushing it to the direction of the arrow).
2. Be sure that the attached blade mylars
come at the bottom side of the recovery
blade and the blade sheet.
e-STUDIO281c/351c/451c
TRANSFER UNIT
/ Blade seal
/ Blade mylar
Blade seal
Blade mylar
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
14 - 14
05/08
Transfer belt cleaning blade
Fig. 14-21
Recovery blade
Blade seal
Fig. 14-22
Recovery blade
Blade sheet
Blade mylar
Fig. 14-23