Testing The Printhead Fan; Testing Transport And Duplex Motors; Troubleshooting Motors (Laminator); Troubleshooting Other Devices - DataCard CP80 Plus Service Manual

Card printers
Table of Contents

Advertisement

Testing the Printhead Fan

To test the printhead fan, it can be connected to the cam motor's connection.
These two motors are not compatible, but the driver circuitry for the cam motor
will operate the fan.
CAUTION: You cannot connect the cam motor into the fan's connector. The
circuitry of the control board will be damaged.

Testing Transport and Duplex Motors

The two stepper motors cannot be tested using the methods presented above.
The only reliable way of verifying if the motor is non-functional is to replace the
motor with an identical motor.

Troubleshooting Motors (Laminator)

The motors in the laminator are not as accessible or as compatible as the motors
in the printer assembly. Swapping motors in the laminator section is limited due
to the cable lengths of the wires. The best solution for testing a motor in the
laminator section is to connect a spare motor from parts inventory.
Except for limitations in cable length, the two heater lift motors are
interchangeable and the two foil transport motors are interchangeable. However,
it is important to note that the main transport motor is not interchangeable with
any other motor in the laminator.

Troubleshooting Other Devices

Testing the Smart Card Solenoid

The driving circuitry for the smart card solenoid is located on the smart card
daughter board. A power transistor on the daughter board amplifies the signal
going to the solenoid. If the solenoid is not receiving a signal, the daughter board
is the likely cause. To verify that the solenoid itself is functioning, plug it into the
cam motor's connector.
CAUTION: Do not attempt to connect the solenoid into the printhead fan's
connector, as this may damage the fan's driving circuitry.
CP80 and CP80 Plus Service Manual
4-9