Upper Duplex Rotational Adjustment - DataCard CP80 Plus Service Manual

Card printers
Table of Contents

Advertisement

Upper Duplex Rotational Adjustment

This adjustment sets the Upper Duplex Home offset. The Duplex Print Return
and Duplex Handoff offsets are adjusted based on the resulting value of the
Duplex Home offset.
Adjustment Procedure
1.
From Diagnostics, select Printer and then Step Test.
2.
Click on the Move duplex to home position button. The flipper will rotate
and re-register at the home position.
3.
Open a second instance of diagnostics and go to the Printer Values window.
4.
Examine the physical position of the duplex calibration pointer. The proper
location of the pointer is at the letter "E" on the duplex chassis.
5.
Verify the setting by re-homing the duplex in diagnostics.
6.
Set the other parameters based on the new Home offset. The table below
shows what should be added or subtracted from the Home offset's value. For
example, the Handoff offset should be 77 units larger than the Home offset.
Duplex Home Offset
Duplex Print Return Offset
Duplex Handoff Offset
7.
Save the values to Power-on defaults.
CP80 and CP80 Plus Service Manual
If the pointer is right of the "E", add the number of units to the current
setting (each letter represents 2 units because every other letter is shown).
If the pointer is left of the "E", subtract the number of units from the
current setting.
Parameter
Change
Sample
Baseline
Add 6
Add 77
17
23
94
5-53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp80Sp75