Mitsubishi Electric GENERAL PURPOSE AC SERVO MR-E- A/AG Instruction Manual page 293

General-purpose ac servo
Table of Contents

Advertisement

15. MR-E-
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Class No. Symbol
58
NH1
Machine resonance suppression filter 1
Used to selection the machine resonance suppression filter.
(Refer to Section 8.2.)
59
NH2
Machine resonance suppression filter 2
Used to set the machine resonance suppression filter.
0
Name and function
0
Notch frequency selection
Set "00" when you have set adaptive vibration
suppression control to be "valid" or "held"
(parameter No. 60:
Setting
Frequency
Setting
Frequency
value
value
00
Invalid
08
562.5
01
4500
09
500
02
2250
0A
450
03
1500
0B
409.1
04
1125
0C
375
05
900
0D
346.2
06
750
0E
321.4
07
642.9
0F
300
Notch depth selection
Setting
value
0
1
2
3
Notch frequency
Same setting as in parameter No. 58
However, you need not set "00" if you have
set adaptive vibration suppression control to
be "valid" or "held".
Notch depth
Same setting as in parameter No. 58
1
or
2
Setting
Frequency
Setting
value
value
10
281.3
18
11
264.7
19
12
250
1A
13
236.8
1B
14
225
1C
15
214.3
1D
16
204.5
1E
17
195.7
1F
Depth
Gain
40dB
Deep
14dB
to
8dB
Shallow
4dB
15 - 48
Initial
Unit
value
0000
).
Frequency
187.5
180
173.1
166.7
160.1
155.2
150
145.2
0000
Setting
Control
range
mode
S T
Refer to
Name
and
function
column.
S T
Refer to
Name
and
function
column.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-e-*aMr-e-*agMr-e- a seriesMr-e- ag series