5. PARAMETERS
Class No. Symbol
43
*DI2
Input signal selection 2 (CN1-4)
Allows any input signal to be assigned to CN1-pin 4.
Note that the setting digit and assigned signal differ according to the
control mode.
0 0
Signals that may be assigned in each control mode are indicated
below by their symbols.
Setting of any other signal will be invalid.
Note: P: Position control mode
This parameter is unavailable when parameter No.42 is set to assign
the control change (LOP) to CN1-pin 4.
This parameter is unavailable when parameter No. 48 is set to assign
the Forward rotation stroke end (LSP) and Reverse rotation stroke end
(LSN) to be assigned to CN1-pin 4.
Name and function
Position
control mode
Internal speed
control mode
(Note) Control mode
Set value
P
0
1
SON
RES
2
PC
3
4
CR
5
6
7
8
9
A
B
CM1
CM2
C
D
TL1
E
CDP
F
S: Internal speed control mode
Input signals of
CN1-pin 4
selected.
S
SON
RES
PC
CR
SP1
SP2
ST1
ST2
SP3
TL1
CDP
5 - 16
Initial
Setting
Control
Unit
value
range
mode
0111
Refer to
Name
and
function
column.
P S