Troubleshooting - Mitsubishi Electric GENERAL PURPOSE AC SERVO MR-E- A/AG Instruction Manual

General-purpose ac servo
Table of Contents

Advertisement

10. TROUBLESHOOTING

No.
Start-up sequence
4
Gain adjustment
5
Cyclic operation
Note: Switch power on again after making sure that the charge lamp has turned off completely.
Fault
Rotation ripples
Make gain adjustment in the
(speed fluctuations)
following procedure:
are large at low
1. Increase the auto tuning
speed.
response level.
2. Repeat acceleration and
deceleration several times
to complete auto tuning.
Large load inertia
If the servo motor may be
moment causes the
run with safety, repeat
servo motor shaft to
acceleration and
oscillate side to side.
deceleration several times to
complete auto tuning.
Position shift occurs Confirm the cumulative
command pulses, cumulative
feedback pulses and actual
servo motor position.
Investigation
Gain adjustment fault
Gain adjustment fault
Pulse counting error, etc.
due to noise.
10 - 2
Possible cause
Chapter 7
Chapter 7
(2) in this
section
Refer to

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-e-*aMr-e-*agMr-e- a seriesMr-e- ag series

Table of Contents