Signal Explanations - Mitsubishi Electric GENERAL PURPOSE AC SERVO MR-E- A/AG Instruction Manual

General-purpose ac servo
Table of Contents

Advertisement

15. MR-E-
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

15.2.4 Signal explanations

For the I/O interfaces (symbols in I/O column in the table), refer to Section 3.6.2.
In the control mode field of the table
S: speed control mode, T: Torque control mode
: Denotes that the signal may be used in the initial setting status.
: Denotes that the signal may be used by setting the corresponding parameter among parameters 43 to
49.
The pin No.s in the connector pin No. column are those in the initial status.
(1) Input signals
Signal
Symbol
Forward rotation
LSP
stroke end
Reverse rotation
LSN
stroke end
Outside torque
TL
limit selection
Internal
TL1
torque limit
selection
POINT
The acceptance delay time of each input signal is less than 10ms.
Connec-
tor pin
No.
CN1
To start operation, short LSP-SG and/or LSN-SG. Open them to
6
bring the motor to a sudden stop and make it servo-locked.
Set "
1" in parameter No. 22 to make a slow stop.
(Refer to Section 5.2.3.)
(Note) Input signals
LSP
LSN
1
1
0
1
CN1
1
0
7
0
0
Note. 0: LSP/LSN-SG off (open)
1: SP/LSN-SG on (short)
Set parameter No. 41 as indicated below to switch on the signals
(keep terminals connected) automatically in the servo amplifier:
Parameter No.41
1
1
Turn TL off to make Internal torque limit 1 (parameter No. 28)
valid, or turn it on to make Analog torque limit (TLA) valid.
For details, refer to (1)(C), Section 15.2.5.
When using this signal, make it usable by making the setting of
parameter No. 43 to 48.
(Refer to (5), Section 3.4.1.)
Functions/Applications
Operation
CCW
CW
direction
direction
Automatic ON
LSP
LSN
15 - 14
Control
I/O
mode
division
S
T
DI-1
DI-1
DI-1