15. MR-E-
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Class No. Symbol
41
*DIA
Input signal automatic ON selection
Used to set automatic servo-on (SON) forward rotation stroke end
(LSP) reverse rotation stroke end (LSN).
0
42
*DI1
Input signal selection 1
Used to assign the control mode changing signal input pins and to set
the clear (CR).
0 0 0
Name and function
Servo-on (SON) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
Forward rotation stroke end (LSP)
input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
Reverse rotation stroke end (LSN)
input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
Control change (LOP) input pin
assignment
Used to set the control mode
change signal input connector
pins. Note that this parameter is
made valid when parameter No.
0 is set to select the position/int-
ernal speed change mode.
Set value
0
1
2
3
4
If forward rotation stroke end (LSP) or reverse rotation stroke
end (LSN) is assigned to any pin with parameter No. 48, this
parameter cannot be used.
Connector pin No.
CN1-4
CN1-3
CN1-5
CN1-6
CN1-7
15 - 42
Initial
Setting
Control
Unit
value
range
mode
0000
Refer to
Name
and
function
column.
0002
Refer to
Name
and
function
column.
S T
S
S/T