Mitsubishi Electric GENERAL PURPOSE AC SERVO MR-E- A/AG Instruction Manual page 281

General-purpose ac servo
Table of Contents

Advertisement

15. MR-E-
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Class No. Symbol
17
MOD
Analog monitor output
Used to selection the signal provided to the analog monitor
(MO1) analog monitor (MO2) output. (Refer to Section 5.2.2)
18
*
Status display selection
DMD
Used to select the status display shown at power-on.
Name and function
0
0
Setting
Analog monitor 2 (MO2)
0
Servo motor speed ( 8V/max. speed)
1
Torque ( 8V/max. torque)
2
Servo motor speed ( 8V/max. speed)
3
Torque ( 8V/max. torque)
4
Current command ( 8V/max. current command)
5
Cannot be used.
6
7
8
9
A
B
0 0
Selection of status display at
power-on
0: Cumulative feedback pulses
1: Servo motor speed
2: Cannot be used
3: Cannot be used
4: Cannot be used
7: Regenerative load ratio
8: Effective load ratio
9: Peak load ratio
A: Instantaneous torque
B: Within one-revolution position low
C: Within one-revolution position high
D: Load inertia moment ratio
E: Bus voltage
Status display at power-on in
corresponding control mode
0: Depends on the control mode.
Control Mode
Speed/torque
1: Depends on the first digit setting of this parameter.
Analog monitor 1 (MO1)
Speed
Servo motor speed/analog torque command voltage
Torque
15 - 36
Initial
Unit
value
0100
0000
Status display at power-on
Servo motor speed
Analog torque command voltage
Setting
Control
range
mode
S T
Refer to
Name
and
function
column.
S T
Refer to
Name
and
function
column.