When Alarm Or Warning Has Occurred; Alarms And Warning List - Mitsubishi Electric GENERAL PURPOSE AC SERVO MR-E- A/AG Instruction Manual

General-purpose ac servo
Table of Contents

Advertisement

10. TROUBLESHOOTING

10.2 When alarm or warning has occurred

10.2.1 Alarms and warning list

When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or
warning has occurred, refer to Section 10.2.2 or 10.2.3 and take the appropriate action.
Set "
1" in parameter No. 49 to output the alarm code in ON/OFF status across the corresponding
pin and SG. Warnings (AL.96 to AL.E9) have no alarm codes. Any alarm code is output at occurrence of
the corresponding alarm. In the normal status, the signals available before alarm code setting (CN1-12:
ZSP, CN1-11: RD, CN1-10: INP or SA) are output.
After its cause has been removed, the alarm can be deactivated in any of the methods marked
alarm deactivation column.
(Note 2) Alarm code
Display
CN1-10
pin
AL.10
0
AL.12
0
AL.13
0
AL.15
0
AL.16
1
AL.17
0
AL.19
0
AL.1A
1
AL.20
1
AL.24
0
AL.30
0
AL.31
0
AL.32
0
AL.33
0
AL.35
0
AL.37
0
AL.45
1
AL.46
1
AL.50
1
AL.51
1
AL.52
0
AL.8A
0
AL.8E
0
88888
0
AL.E0
AL.E1
AL.E6
AL.E9
Note: 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. 0: off
1: on
POINT
Configure up a circuit which will detect the trouble (ALM) signal and turn
off the servo-on (SON) signal at occurrence of an alarm.
CN1-11
CN1-12
pin
pin
1
0
Undervoltage
0
0
Memory error 1
0
0
Clock error
0
0
Memory error 2
0
1
Encoder error 1
0
0
Board error
0
0
Memory error 3
0
1
Motor combination error
1
0
Encoder error 2
0
1
Main circuit error
1
0
Regenerative error
1
1
Overspeed
0
1
Overcurrent
1
0
Overvoltage
1
1
Command pulse frequency error
0
0
Parameter error
1
0
Main circuit device overheat
1
0
Servo motor overheat
1
0
Overload 1
1
0
Overload 2
1
1
Error excessive
0
0
Serial communication time-out error
0
0
Serial communication error
0
0
Watchdog
Excessive regenerative warning
Overload warning
Servo emergency stop warning
Under voltage warning
Name
10 - 5
Alarm deactivation
Press
"SET" on
Power
current
OFF ON
alarm
screen.
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
Removing the cause of occurrence
deactivates the alarm
automatically.
in the
Alarm
reset
(RES)
signal
(Note 1)
(Note 1)
(Note 1)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-e-*aMr-e-*agMr-e- a seriesMr-e- ag series

Table of Contents