6. DISPLAY AND OPERATION

6.3 Diagnostic mode

Name
Sequence
External I/O signal
display
Output signal (DO)
forced output
Jog feed
Positioning
operation
Test
operation
mode
Motorless
operation
Machine
analyzer
operation
Software version low
Software version high
Manufacturer setting
screen
Motor series
Motor type
Encoder
Display
Refer to section 6.6.
Not ready.
Indicates that the servo amplifier is being initialized or an alarm
has occurred.
Ready.
Indicates that the servo was switched on after completion of
initialization and the servo amplifier is ready to operate.
Indicates the ON-OFF states of the external I/O signals.
The upper segments correspond to the input signals and the
lower segments to the output signals.
Lit: ON
Extinguished: OFF
The I/O signals can be changed using parameters No. 43 to 49.
The digital output signal can be forced on/off. For more
information, refer to section 6.7.
Jog operation can be performed when there is no command from
the external command device.
For details, refer to section 6.8.2.
The servo configuration software (MRZJW3-SETUP154E) is
required for positioning operation. This operation cannot be
performed from the operation section of the servo amplifier.
Positioning operation can be performed once when there is no
command from the external command device.
Without connection of the servo motor, the servo amplifier
provides output signals and displays the status as if the servo
motor is running actually in response to the external input
signal.
For details, refer to section 6.8.4.
Merely connecting the servo amplifier allows the resonance point
of the mechanical system to be measured.
The servo configuration software (MRZJW3-SETUP154E or later)
is required for machine analyzer operation.
Indicates the version of the software.
Indicates the system number of the software.
Screen for manufacturer setting. When this screen is being
displayed, do not press any other buttons than "UP" and "DOWN"
button.
Press the "SET" button to show the motor series ID of the servo
motor currently connected.
Press the "SET" button to show the motor type ID of the servo
motor currently connected.
Press the "SET" button to show the encoder ID of the servo motor
currently connected.