3.7.6. More System Functions
To set the "More System Functions", move the cursor bar to the main menu and select the "More
System Functions" item and then press Enter key. The "More System Functions" menu will show
multiple items. Move the cursor bar to an item, then press Enter key to select the desired function.
3.7.6.1.
Smart Option For HDD
This option is used to increases the reliability of SSDs/HDDs by automatically copying data from
a drive with potential to fail to a designated hot spare or newly inserted drive. The options are:
"Failed The Drive", "Failed The Drive If Hot Spare Exist", and "Alert Only". The default is "Alert
Only".
Multiples Of 1G: If you have 123 GB drives from different vendors; chances are that the
capacity varies slightly. For example, one drive might be 123.5 GB, and the other 123.4
GB. "Multiples Of 1G" truncates the fractional part. This makes the same capacity for
both of these drives so that one could replace the other.
Disabled: It does not truncate the capacity.
"Failed The Drive"- controllers kill off the SMART fail drive immediately.
"Failed The Drive If Hot Spare Exist" – controllers kill off the SMART fail disk if hot spare
dive is existed.
"Alert Only" – it will trigger alert when there happens a SMART fail drive.