CHECKING OPERATION OF THE SOLENOID STARTER

Apply 12 V (battery voltage) across the positive terminal and negative terminal of the connector.
With a multimeter connected between the two poles (threaded pins) of the solenoid starter, check for
electric continuity.
If there is no electric continuity, ensure that the terminals are not oxidised and apply water repellent spray.
Change the solenoid starter if the malfunction persists.

REFITTING THE SOLENOID STARTER

Lay down the starter motor-solenoid starter cable (9) and the solenoid starter-battery cable (10).
Position the two washers (8) and start screws (7).
Tighten the screws (7) to a torque of 10Nm ± 10%.
Refit protection cap (6).