Wiring the Touch Finder

Power Supply Wiring

Connecting the Power Supply
1
Loosen the two terminal screws using a Phillips
screwdriver.
2
Attach crimp terminals to the power lines.
Secure the positive and negative lines as indicated
using M3 screws.
Power supply tightening torque: 0.54 Nm
3
In environments where there is excessive noise, at-
tach a ferrite core (ZCAT1730-0730 from TDK or the
equivalent) to the power supply cable.
Turning ON the Touch Finder
1
Remove the cover from the power switch on the left side of
the Touch Finder.
2
Press the switch toward ON.
Power Supply Specifications
Use a power supply that meets the following specifications. (The power supply is sold separately.)
Item
Power supply voltage
Output current
Recommended Power Supply
External power supply terminal screws
Recommended power line wire size
Important
• Supply power from a DC power supply for which measures have been applied to prevent high voltages (e.g., a
safety extra low voltage circuit).
If UL certification is required for the overall system, use a UL Class II DC power supply.
• When using the FQ-D31, do not connect a switching regulator and AC Adapter (FQ-AC@) at the same time.
28
Wiring
24 VDC
When you attach the ferrite core to
the power supply cable, wrap the
cable only one time.
Description
24 VDC (21.6 to 26.4 V)
0.65 A min.
S8VS-01524@ (24 VDC, 0.65 A)
M4 (tightening torque: 1.2 Nm)
AWG16 to AWG22 (length of 5 m max.)
+
2
ON
1
OFF
FQ User's Manual