Omron FQ-CR1 User Manual page 56

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

Note
Output function of the read results
• The output order
If both the calculation and reading results are being output via Ethernet, the reading result (text string) is output after
the calculation result is output.
Example: Output of read results together with two expressions
Read result: ABC
[Expression] - [Data0]: 123
[Expression] - [Data1]: 456
The output order is as follows:
123 (field separator) 456 (record separator) ABC (record separator) CR
• Code conversion
The following character codes need to be converted for output. The texts after conversion are output.
Character code
Space
CR
LF
NULL
FF
Setting Decode Settings
Press [Decode settings].
Be sure to always specify the code type. Specify other items as necessary. If master data is automatically
registered, the code type, the composite codes on/off setting, and the read direction are automatically set.
Setup Item
Code type
Timeout
Composite codes on/off
Check digit on/off
Direction
Reverse on/off
54
Reading Bar Codes
Before conversion
After conversion
&h20
&h8540
&h0D
&h8541
&h0A
&h8542
&h00
&h8543
&hFF
&h8544
Setting Value
JAN/EAN/UPC (default
value)
Code39
Codebar
ITF
Code93
Code128/GS1-128
GS1 DataBar
Pharmacode
1 to 9999 ms (default value:
9999)
OFF (default value)
ON
OFF
ON (default value)
Horizontal mode (default
value)
Vertical mode
OFF (default value)
ON
Description
Selects the type of barcode to be read.
Sets the timeout time in read processing. A read error occurs if measure-
ment does not end after the preset timeout time is
exceeded.
Sets whether or not to support composite codes.
This item is enabled only when the following barcode types are selected:
Code128/GS1-128, GS1-DataBar
Selects whether or not to insert a check digit. This item is enabled only
when the following barcode types are selected: Codebar, Code39, ITF
(Interleaved 2 of 5). When the other
codes are selected, this item is set to ON.
Selects the reading direction. This item is enabled only when Pharma-
code is selected as the barcode type.
Sets whether or not to use the reverse mode. This item is enabled only
when Pharmacode is selected as the barcode type.