Detail Settings
[Inspect]  [Inspection]  [Add item.]  [2D-code]  [Details] Tab Page
Press [Function settings].
Setting Function Settings
Set the function settings (verification on/off, verified master data, partial verif. on/off, partial verification setup,
string output on/off, error string, partial output on/off and output string setup).
Specify these settings as necessary.
Setup Item
Setting Value
Verification on/off
OFF (default value)
ON
Verified master data
All master data (default
value)
Master data 0 to 31
Partial verif. on/off
OFF (default value)
ON
Partial verification setup
1 to 1024 (default value
first digit:1 last digit:1024)
String output on/off
OFF (default value)
ON
Error string
Max. 20 digits (default value:
NG)
Partial output on/off
OFF (default value)
ON
Output string setup
1 to 1024 (default value
first digit:1 last digit:1024)
FQ User's Manual
Description
When set to ON, verification with the master data is executed.
Selects the model (master data) to be used for verification.
The number of digits in the read results to be verified with the master
data can be limited. When [Partial verification] is set to ON, set the first
and last compared digit positions. Up to 32 characters can be set as the
number of digits.
Example: First compared digit 2, last compared digit 6
O M R O N 2 0 0 8
6th digit
2nd digit
The text string used for verification becomes "MRON2".
Sets whether or not to output the reading result via Ethernet.
Sets the text string to be output when a read error occurs.
ASCII code table: p. 58
Sets whether or not to specify a range in the read data to output from
when [Output characters] is set to ON.
Sets the first and last digit positions to output. If the read text string con-
tains non-targeted digits, the error string is output.