7-5 Saving Sensor Settings

The Sensor settings are saved in flash memory inside the Sensor.
This section describes how to back up the settings in and restore them from an SD card or other external
memory.
Backing Up Settings in External Memory
(Setup Mode)  [Save to file]  [Setting] Tab Page
1
Press the data to save.
2
Enter the file name in 15 characters or less.
After entering the file name, press [OK]. The data will be
saved and the display will return to [Save to file].
Applicable Data
Data
Scene data (The file name
extension is SCN.)
Scene group data (The file
name extension is SGP.)
Sensor system data (The file
name extension is SYD.)
All Sensor data (The file
name extension is BKD.)
Touch Finder data (The file
name extension is MSD.)
For the PC Tool, data will be saved in the following folder: \\..\My Documents\OMRON FQ
Restoring Data to the Sensor from External Memory
(Setup Mode)  [Load from file]
1
Press the data to be restored.
2
The selected data will be read from external memory
and displayed.
Press the file to load.
FQ User's Manual
Storage location
\sensor_name\SCN
The following data is backed up for each scene.
• Settings for all inspection items
• Order of inspection items
\sensor_name\SGP
All scene data is backed up.
\sensor_name\SYD
All system data in the Sensor is backed up.
The system data is the same for all scenes.
\sensor_name\BKD
All settings in the Sensor (all scene data and Sensor system data) is
backed up.
\MSD
All settings in the Touch Finder are backed up.
Description

Saving Sensor Settings