Run Mode
Menu command
Graphic
Graphics + Details
Statistical data
All results/Region
Trend Monitor
Histogram
Adjust judgement
(Except for statistical
data)
Auto display
(trend monitor and
histogram only)
Display range
(trend monitor and
histogram only)
Number of data
(trend monitor only)
Number of data
(histogram only)
Clear results
(graphic or graphic +
details list)
Delete stats (total
data)
Image logging
Data logging
TF settings
Sensor setting
Multi sensor
NG sensor
Select
Connections
Auto
connect
170
Menu Tables
Description
Displays the input image.
Displays the inspection item individual
judgement results and measurement val-
ues.
Displays the total number of measure-
ments and the total number of NG overall
judgements and the NG ratio from when
the power supply was turned ON.
Displays the inspection item individual
judgement results for all inspection
items.
Displays the individual judgement results
saved in the Sensor in a trend monitor.
Displays the individual judgement results
saved in the Sensor in a histogram.
Adjusts judgement parameters without
stopping measurements.
Automatically sets the display range
according to the measurement results.
Changes the display range of measure-
ment values.
Changes the number of displayed mea-
surement values.
Changes the number of displayed mea-
surement values (i.e., the vertical display
range of the histogram).
Clears the measurement results of the
inspection items.
Clears the total results of the inspection
items.
Starts and stops logging in external
memory.
The same as for Setup Mode. (This does not apply to the PC Tool.)
The resolution of the measurement image can be set on the PC Tool.
Switches to Setup Mode.
Simultaneously displays the images for
multiple connected Sensors.
From multiple connected Sensors, dis-
plays the image of only the Sensors with
NG results.
Switches to the selected Sensor.
Displays the name of the Sensor
detected by the Touch Finder and the
connection status.
Automatically detects and connects the
Sensors that are connected.
Setting range
---
---
OFF or ON (default)
-999,999,999 to 999,999,999
200, 400, or 1,000 (default: 200)
5 to 1,000
---
---
ON: Start or OFF: Stop
ON: Start or OFF: Stop
---
---
---
---
Data
Refer-
ence
---
p. 82
---
---
---
p. 84
---
p. 85
---
p. 87
---
p. 84,
p. 85
p. 84,
p. 85
p. 84
---
p. 85
---
---
---
---
---
p. 96
---
---
p. 109
---
p. 80
---
p. 82
---
---
---