Omron FQ-CR1 User Manual page 117

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

• I/O Signal Allocations
Signal
Output signals
OUT0 (OR signal)
OUT1 (BUSY signal)
Input signals
TRIG
Important
The BUSY signal will remain ON while the measurement is being executed.
Performing Continuous Measurements
Continuous measurements are performed while the continuous measurement command is input from an
external device.
Immediately after a measurement is performed, the next measurement is performed.
This is repeated while a continuous measurement command is input with the IN0 to IN5 signals.
PLC
Note
This function can be used only when the input mode is set to Expanded Mode.
Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Black
OUT0 (OR)
Orange
OUT1 (BUSY)
FQ User's Manual
Address
CIO 0.00
CIO 0.01
CIO 1.00
(1) IN5 signal ON (IN0 to IN4 are OFF)
Or other
device
State
Description
OFF
Command parameters for continu-
ous measurements
OFF
OFF
OFF
OFF
ON
Command input for continuous
measurements
--
Overall judgement (default assign-
ment)
--
Processing in progress (default
assignment)
(2) Performs continuous
measurements
The signals shown at the left
are used.
Refer to the following informa-
tion for signal wiring.
Wiring: p. 26
Controlling/Outputting in Parallel
115