Outputting the Calculation Results
The overall judgement (JG) of the calculations are reflected in the overall judgement of the inspection item. The
calculation results (D0 to 31) can be output as Ethernet outputs or it can be output by using logging.
Inspection items*
(I0 to I31)
Data
* The position compensation values
Calculation
can also be referenced as data.
Process
Calculation (Z0)
Calculation
Expression 0
results (D0)
Calculation
Expression 31
results (D31)
No-protocol Output
p. 129
Ethernet output
The results can be allocated
to data 0 to 31 for Ethernet
output.
FQ User's Manual
• Data logging
• Judgement results
• Reference values
• Reference values
Upper and lower
limit judgement
Upper and lower
limit judgement
Logging
p. 96
SD card/
Computer
The results can be
recorded as logging data.
Calculations and Judgements Using Inspection Item Data
Individual
judgement results
(OR0 to OR31)
Calculation judgement
result (J0)
Overall judgement
result of calcula-
OR logic
tions (JG)
Calculation judgement
result (J31)
Overall judgement
result (OR)
Reflected in the overall
judgement result.