4-4 Reading Bar Codes
Bar Codes
Bar codes are read and verified.You can output the result of reading and/or verifying bar codes to external
devices.The following nine code types can be read.
JAN/EAN/UPC, Code39, Codabar (NW-7), ITF (Interleaved 2 of 5), Code 93, Code128/GS1-128, GS1
DataBar* (Truncated, Stacked, Omni-directional, Stacked Omni-directional, Limited, Expanded, Expanded
Stacked), Pharmacode, GS1-128 Composite Code (CC-A,CC-B,CC-C)
* GS1 DataBar is a code in which the name has been changed from the previous RSS.
Note
Setup
Draw the measurement region, then execute
AUTO setting. The barcode type and some of the
decode conditions are automatically set.
Important
Reading will end in error if the barcode type is incorrectly set. Set the barcode type before starting reading. When
AUTO setting is executed, the captured barcode is read, and the following items can be set:
• Code type
• Direction (for Pharma only)
• Reverse decode (for Pharma only)
50
Reading Bar Codes
Measurement region
Setting Decode Settings: p. 54
Setting Decode Settings: p. 54
Setting Decode Settings: p. 54
Measurement
One barcode is read in a single measurement region.
When the measurement region contains multiple bar-
codes, the result of the first barcode to be read is out-
put.
FQ User's Manual