Omron FQ-CR1 User Manual page 155

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

Communications Example
An example of the communications log when a computer is connected and communications is performed with
a no-protocol command from a terminal application is shown below.
Example 1: Changing Scenes (Scene number 1 is specified.)
S 1
Space
OK
Example 2: Acquiring inspection item data (Acquires the 2D-code judgement result registered to inspection
item 10)
ITEMDATA 10 0
Space
0
OK
Example 3: Measurement when Ethernet Output Is Not Set
M
OK
Example 4: Measurement when Ethernet Output Is Set
M
OK
1.0000
0.0000
M
OK
2.0000
0.0000
FQ User's Manual
0.0000
306.0000
0.0000
0.0000
Outputting/Controlling with Ethernet
153