Omron FQ-CR1 User Manual page 62

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

Note
Output function of the read results
• The output order
If both the calculation and reading results are being output via Ethernet, the reading result (text string) is output after
the calculation result is output.
Example: Output of read results together with two expressions
Read result: ABC
[Expression] - [Data0]: 123
[Expression] - [Data1]: 456
The output order is as follows:
123 (field separator) 456 (record separator) ABC (record separator) CR
• Code conversion
The following character codes need to be converted for output. The texts after conversion are output.
Character code
Space
CR
LF
NULL
FF
Setting Decode Settings
Press [Decode settings].
Be sure to always specify the code type. Specify other items as necessary. If master data is automatically
registered, the code type, the composite component, and the direction (Pharma) are automatically set.
Setup Item
Code type
Timeout
Reverse
Code color
Shape (Data Matrix)
60
Reading 2D-codes
Before conversion
After conversion
&h20
&h8540
&h0D
&h8541
&h0A
&h8542
&h00
&h8543
&hFF
&h8544
Setting Value
Data Matrix
QR Code
MicroQR Code
PDF417
MicroPDF417
Maxi Code
AZtec Code
Codablock
1 to 9999 ms
(default value: 9999)
Normal (default value)
Reverse
Black
White
Auto (default value)
Square (default value)
Square or Rectangle
Description
Selects the type of 2D Code to be read.
Sets the timeout time in read processing. A read error occurs if measure-
ment does not end after the preset timeout time is
exceeded.
Sets normal or reverse as the image orientation.
Specifies the code color.
This item is enabled only when the following barcode types are selected:
Data Matrix, PDF417
Specifies the code shape.
This item is enabled only when the following barcode types are selected:
Data Matrix
FQ User's Manual

Advertisement

Table of Contents
loading

Table of Contents