Omron FQ-CR1 User Manual page 163

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

Menu command
Insp. region
width
Master
data 0 to
31
Auto
Manual Manually registers the master data.
Clear
Copy
Rename
Insp. region
width
Master
data 0 to
31
Auto
Manual Manually registers the master data.
Clear
Copy
Rename
Judgement
Num. of charac-
ters
(For bar code)
Characters
(For bar code)
Num. of charac-
ters
(For 2D-code)
Characters
(For 2D-code)
FQ User's Manual
Description
Adjusts the size and position of the
measurement region.
Selects the number of the master data
to be registered.
Automatically registers the master data. ---
Deletes/copies the master data or
changes the name of the master data.
Adjusts the size and position of the
measurement region.
Selects the number of the master data
to be registered.
Automatically registers the master data. ---
Deletes/copies the master data or
changes the name of the master data.
Used to specify the parameters for an
OK judgement for individual judgements.
The range for the reference value to
judge OK is specified.
Setting range
---
---
---
---
---
---
---
---
---
---
0 to 100
(Defaults: Upper limit: 100, Lower limit:
60)
1 to 1024
(Defaults: Upper limit: 1024, Lower limit:
1)
32 characters max.
(Default*)
1 to 1024
(Defaults: Upper limit: 1024, Lower limit:
1)
32 characters max.
(Default*)
Data
Refer-
ence
Scene
p. 51
Scene
p. 51
Scene
p. 51
Scene
p. 51
Scene
---
Scene
p. 57
Scene
p. 57
Scene
p. 57
Scene
p. 57
Scene
---
Scene
---
p. 52
p. 58
161
Menu Tables

Advertisement

Table of Contents
loading