Omron FQ-CR1 User Manual page 134

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

Note
Measurement data of inspection items for which logging is not supported can be logged by using the Ethernet output
settings. Set the measurement data of inspection items for which logging is not supported as calculation parameters
using the Calculation menu command, and use them as the calculation results. Allocate the results to Ethernet out-
puts. In this way, measurement data can be logged as calculation results.
Outputting Data to an External Device Using No-protocol Communications
Setting the Data To Output Automatically
Refer to Setting the Data to Output via Ethernet.
Setting the Data Format
[In/Out]  [I/O setting]  [Ethernet]
1
Press [Output form].
2
Set the output format to ASCII or binary.
3
Set the data format.
 When Output Format Is ASCII
Set the parameters for integer digits, decimal digits, negative numbers, 0 suppression, the field separator,
and the record separator.
 Output Format
Measured value of
data 0
Note
The data output method, digits, and data separators can be changed as needed.
Example: Integer digits: 5, decimal digits: 3, negative number expression:, field separator: comma, record
separator: CR
1
2
3
4 5
.
6 7
Measured value of data 0
Field separator
*1 Because the record separator is set to CR, only one record is output for each measurement. A blank line (CR:
delimiter) will therefore be entered after the record separator. If you do not want a blank line, set the record sepa-
rator to None.
132
Outputting/Controlling with Ethernet
Measured value of
,
data 1
8
,
5
6
7
.
3
2
1
Measured value of data 1
Measured value of
,
· · ·
data 7
,
7
6
.
9
2
1
Measured value of data 2
CR
,
,
6 5
9 8 7
.
1
6 5 CR
Measured value of data 7
Record separator
FQ User's Manual
*1
CR
Delimiter