Omron FQ-CR1 User Manual page 122

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

Adjusting the Judgement Output Timing
The output timing of the OR signal or OR0 to OR31 signals can be selected from two modes depending on the
external device.
Selecting the OFF Timing
• Level output (default)
The status of the output OR signal is held until the next OR signal is output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
ON
OR signal
OFF
• One-shot output
The status of the output OR signal is turned OFF after a specified time has passed. (Setting range: 0 to 1,000 ms)
ON
TRIG signal
OFF
ON
BUSY signal
OFF
ON
OR signal
OFF
Delaying the Output Timing
When using one-shot output, the output timing of the OR signal can be delayed. (Setting range: 0 to 1,000 ms)
ON
TRIG signal
OFF
ON
BUSY signal
OFF
ON
OR signal
OFF
(Output polarity: ON for NG)
120
Controlling/Outputting in Parallel
ON for 1 ms min.
ON while measure-
ments are being
processed (depends
on BUSY output
conditions)
Overall judgement
(Output polarity: ON for NG)
ON for 1 ms min.
ON while
measurements are
being processed
(depends on BUSY
output conditions)
Overall judgement
(Output polarity: ON for NG)
ON for 1 ms min.
ON while
measurements are
being processed
(depends on BUSY
output conditions)
Overall judgement
output delay
NG
Held until the next
judgement result is output
NG
One-shot
output time
Turns OFF.
NG
One-shot
One-shot
output time
OK
OK