Omron FQ-CR1 User Manual page 99

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

Item
Image logging
Data logging
Note
The logging parameter settings are the same for file logging and recent results logging.
Starting and Stopping Logging
After logging is started (i.e., set to ON), the specified image data and measurement data will be saved in the
SD card or computer hard disk each time measurements are performed.
(Run Mode)
1
Press [Logging].
2
Press [Image logging] or [Data logging].
3
Press [ON] to start logging.
Press [OFF] to stop logging.
4
Press [Back].
Saved Log Data
• Storage Locations and File Names for Logged File Data
Data
Storage location
Image logging
\sensor_name\
LOGIMAGE\number
Data logging
\sensor_name\LOGDATA
*1: A five-digit number is assigned as a name to the image data storage folder in the order of folder creation as
shown below.
Up to 100 images are stored in each folder.
00000
00001
:
:
*2: Files are stored in the following folder when the PC Tool is used.
\My Documents\OMRON FQ\ SDCard
• File format
Image logging: Image data is saved in a special format for OMRON Vision Sensors. (The file name extension
is IFZ.)
Data logging: Measurement data is saved in the following CSV format.
<Date*1>,<Time*1>,<Measurement value for inspection item 0>,<Measurement value for inspection item 1>,...,<Measurement value for inspection item 31>,
<D0 of expression 0>, ..., <D31 of expression 31>Delimiter
FQ User's Manual
• All: All images will be logged regardless of the measurement results.
• Only NG: Only images for which the overall judgement was NG will be logged.
• None: No images will be logged (default).
• All: All measurement data (Measured values and calculation results) will be logged regardless of the
measurement results.
• Only NG: Only measurement data (Measured values and calculation results) for which the overall
judgement was NG will be logged.
• None: No measurement data (Measured values and calculation results) will be logged (default).
File name
YYYY_MM_DD-HH_MM_SS.IFZ
*1, *2
Example: The following name would be used for measurements performed at
10:10:21 pm on March 10, 2010.
2010_03_10-22_10_21.IFZ
*2
YYYY_MM_DD-HH_MM_SS.CSV
Example: The following name would be used for measurements performed at
10:10:21 pm on March 10, 2010.
2010_03_10-22_10_21.CSV
Field separator
Record separator
Description
Logging Measurement Data and Image Data
97

Advertisement

Table of Contents
loading

Table of Contents