Item No.
U168

Checking/clearing the fuser drive time

Description
Displays or clears the fuser drive time.
Purpose
To check the fuser drive time after replacing the fuser unit.
Method
1. Press the start key. The fuser drive time is displayed.
Press
Release
Clearing
1. Press [Clear].
2. Press the start key. The drive time is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U169

Checking/setting the fuser power source

Description
Displays and settings the specification of fuser power supply for checking.
Purpose
To check or set the specification of fuser power supply after replacement of the fuser unit.
Method
1. Press the start key.
2. Select the mode.
Display
Mode
1: 100 V specifications 2: 200 V specifications 3: 120 V specifications
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Display
Fuser unit drive time (press)
Fuser unit drive time (release)
Specification of fuser power supply
Description
Description
Description
1-3-101
2LK/2LN/2LM/2LC
Setting range
1 to 3