2) Background fogging
Defective area
Step
Density reproduc-
1
tion
Background repro-
2
duction
Printer section
3
Scanner
4
Auto-toner
5
6
High-voltage trans-
7
former (Main
charger / Developer
bias)
Developer unit
8
Developer material/
9
Toner/Drum
10
11
Drum cleaning
12
blade
Toner dusting
13
e-STUDIO350/352/353/450/452/453
TROUBLESHOOTING
Check items
Check the reproduction of the image
density.
Check the background reproduction. Adjust the background.
Check test print image (04-113).
Are the original glass, mirrors and
lens dirty?
Is the auto-toner sensor normal?
Is the toner supplied normally?
Is the high-voltage transformer out-
put defective?
Is the contact between the drum and
developer material normal?
Using the specified developer mate-
rial, toner and drum?
Have the developer material and
drum reached their PM life?
Is the storage environment of the
toner cartridge 35°c less without
dew?
Is the drum cleaned properly?
Is toner heaped on the seal of the
developer unit?
5 - 110
Prescription
Adjust the density.
Go to step 4 if there is any problem on
image.
Clean them.
Check the performance of the auto-toner
sensor and readjust.
Check the motor and circuits.
Adjust the output, or replace the trans-
former.
Adjust the doctor-sleeve gap and polarity.
Use the specified developer material, toner
and drum.
Replace the developer material and drum.
Use the toner cartridge stored in the envi-
ronment within specification.
Check the pressure of the drum cleaning
blade.
Remove the toner and clean the developer
unit.