(3)
After winding the wires around the pulleys, attach the wire holder jigs not to loosen the wires.
Notes:
1. When the wire holder jig is attached, make sure that the wire is not shifted or loosened.
2. The wire should come out of the slot of the wire holder jig and be passed under the arm of it.
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
Fig. 3-37
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved