Toshiba e-STUDIO350 Service Handbook page 46

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

Setting mode (08): Refer to
P. 2-82 "2.2.7 Setting mode (08) (e-STUDIO350/450)"
P. 2-144 "2.2.8 Setting mode (08) (e-STUDIO352/353/452/453)"
List print mode (9S): The procedure varies depending on the code.
[9][START]
(Code)
[POWER]
101: Adjustment mode (05)
102: Setting mode (08)
(Code)
103: PM support mode
104: Stored information of pixel counter (toner cartridge reference)
105: Stored information of pixel counter (service technician reference)
106: Error history
PM support mode (6S):
[6][START]
[POWER]
1: Auto-toner adjustment
2: PM Support Screen
Firmware update mode (89): Refer to "6.FIRMWARE UPDATING"
Normal
Control panel
Warming up
check mode
Ready
[POWER]
OFF
*1
To user
*1 Turn OFF the power after using the self-diagnosis modes, and leave the equipment to the user.
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
[START]
[Digital keys]
Key in the first
code to be printed
(Code)
[START]
(Operation started)
[POWER]
ON
[0][1]
[0][3]
[0][4]
Test print
Adjustment
Test mode
mode
State transition diagram of self-diagnosis modes
[START]
[Digital keys]
Key in the last
code to be printed
[POWER] OFF/ON
(Exit)
[0][5]
[0][8]
[9][START]
List print
Setting
mode
mode
mode
Fig. 2-1
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
2 - 26
07/11
[START]
[POWER]
List starts to
OFF/ON
be printed
(Exit)
[6][START]
[8][9]
Firmware
PM support
update mode
mode

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents