[C] Image position adjustment of the primary scanning direction
While pressing [0] and [5] simultaneously, turn the power ON. → (Adjustment Mode)
(1)
(2)
Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3)
Press [FAX] to make a copy at the mode of A3 (LD), 100% and lower drawer.
(4)
Measure the distance B from the left edge of the paper to 10 mm of the copied image of the ruler.
(5)
Check if the distance B is within the range of 10±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps 3. to 5. above.
<Procedure>
(Adjustment Mode) → (Key in the code [306] with the digital keys) → [START]
→ (Key in a value (acceptable values: 0 to 255))
→ Press the [ENTER] or the [INTERRUPT] button (stored in memory).
→ ("100% A" is displayed.)
* The smaller the adjustment value, the more the image is shifted to the left and the distance B
becomes narrower (0.085 mm/step).