Field Service Ver. 1.0 Mar. 2005
5. Mechanical adjustment
5.4

Adjustment of the Elevator Tray Upper Limit Sensor

[1]
[2]
4684fs2509c0
1. Set up the sensor test mode.
2. Turn VR1 on PWB-A FN fully counterclockwise.
3. Using a sheet of paper, block the Elevator Tray Upper Limit Sensor LED (PWB-C FN).
4. Check that LED4 on PWB-A FN turns OFF. If it stays ON, slowly turn VR1 clockwise
and stop turning it as soon as the LED turns OFF.