14. Mechanical adjustment
14. Mechanical adjustment
14.1 Mechanical adjustment of the scanner section
14.1.1
Adjustment of the Scanner Motor Belt
This adjustment must be made in the following case:
• The Scanner Motor Assy has been removed.
• The Scanner Drive Cables have been rewound.
1. Remove the IR Rear Cover.
2. Remove 16 screws and the reinforcement frame.
[1]
[2]
[2]
[3]
300
[2]
[1]
[1]
[1]
4036fs3036c0
[4]
[2]
4036fs3037c0
Field Service Ver. 1.0 Mar. 2005
[1]
[1]
[1]
3. Loosen the three screws that secure
the Scanner Motor mounting bracket
[1].
4. With the Scanner drive gear set
screw [2] located on the right-hand
side as shown on the left, slide the
Scanner Motor Assy [3] to the left
and check that it is returned to the
original position by the tension of the
spring [4]. Perform this step three
times.
5. Tighten the three screws [2] to fix the
Scanner Motor Assy into position.
[1]
4037F2C076DB