C9401: Exposure Lamp's Failure To Turn On; Lamp Turning On At Abnormal Timing; Standard Controller Configuration Failure; Vendor Connection Failure - Konica Minolta bizhub C450 Service Manual

Hide thumbs Also See for bizhub C450:
Table of Contents

Advertisement

Field Service Ver. 1.0 Mar. 2005
16.6.81

C9401: Exposure Lamp's failure to turn ON

16.6.82

C9402: Exposure Lamp turning ON at abnormal timing

Scanner Assy
Flat Cable
Step
Check the flat cable for proper connection and
1
correct or change as necessary.
2
Change Scanner Assy.
3
Change PWB-C.
16.6.83
CA051: Standard Controller configuration failure
MFP Control Board (PWB-MFPC)
Step
Check to see if the following setting has been
correctly made: "Service Mode" → "System 2" →
1
"Image Controller Setting."
If the setting is changed, be sure to turn OFF and
ON the Main Power Switch.
Check the connectors of the MFP Control Board
2
(PWB-MFPC) for proper connection and correct
as necessary.
3
Change PWB-MFPC.
16.6.84
CC001: Vendor connection failure
Control Board (PWB-MC)
Step
Check the Vendor connector for proper connec-
1
tion and correct as necessary.
Check the PWB-MC connector for proper con-
2
nection and correct as necessary.
3
Change PWB-MC
Relevant Electrical Parts
Image Processing Board (PWB-C)
Action
Relevant Electrical Parts
Action
Relevant Electrical Parts
Coin Vendor (Japan)
Coin Vendor Kit (North America, Europe)
Action
16. Malfunction code
WIRING DIAGRAM
Control Signal
(Electrical
Component)
WIRING DIAGRAM
Control Signal
(Electrical
Component)
WIRING DIAGRAM
Control Signal
(Electrical
Component)
Location
Location
Location
365