Field Service Ver. 1.0 Mar. 2005
[3]
[2]
[1]
[5]
[8]
1. Insert the flat cable [2] into the LPH
2. Affix the seal [3] that comes with the
NOTE
• Failure to affix the seal could cause
the flat cable to come off the LPH
Assy.
4036fs2630c0
3. Remove two screws [4] and the
[4]
4036fs2631c0
4. Remove two Screws [6] and Connec-
[6]
[7]
4036fs2533c1
[1] and lock the LPH [1].
LPH Assy to the location shown on
the left.
Guide [5].
tor [7], and remove the guide Assy
[8].