9. Trouble code
9.3.5
C11A2: Storage Roller/Rolls Spacing Motor drive malfunction
Storage Roller Home Position Sensor (PC12-FN)
Storage Roller/Rolls Spacing Motor (M12-FN)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PC12-FN I/O, sensor check
M12-FN operation check when the Main
4
Power Switch is turned OFF and ON.
5
PWB-A FN replacement
9.3.6
C11B0: Stapling Unit Moving Motor drive malfunction
Staple Home Position Sensor (PC14-FN)
Stapling Unit Moving Motor (M6-FN)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PC14-FN I/O, sensor check
Turn OFF the Main Power Switch, move
the Stapling Unit out of its home posi-
4
tion, and turn ON the Main Power
Switch. Operation check of the Stapling
Unit Moving Motor (M6-FN) at this time.
5
PWB-A FN replacement
36
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.0 Mar. 2005
Control Board (PWB-A FN)
WIRING DIAGRAM
Control signal
—
—
PWB-A FN PJ20A-6 (ON)
PWB-A FN PJ8A-5 to 6
—
Control Board (PWB-A FN)
WIRING DIAGRAM
Control signal
—
—
PWB-A FN PJ22A-3 (ON)
PWB-A FN PJ10A-1 to 4
—
Location
(Electrical compo-
nents)
—
—
FS-507 H-6
FS-507 B-2
—
Location
(Electrical compo-
nents)
—
—
FS-507 H-5
FS-507 B-3
—