6. Mechanical adjustment
6.5

Adjustment of the registration loop value

Adjusted range: -5 mm to + 5 mm Default value: 0 (Loop value: 5 mm)
• The loop value is increased by the entered + value and decreased by the entered - value.
• Too much loop value may result in dog-eared document, and too little loop value may
result in askew document.
A. Adjustment Procedure
1. Call the Service Mode to the screen.
2. Touch "ADF."
3. Touch "Registration Loop Adj."
4. Select the registration loop value.
5. Enter the value from the ten-key pad. (Press the "+/-" key to change the +/- code.)
6. Touch "END."
28
Field Service Ver. 1.0 Mar. 2005