Field Service Ver. 1.0 Mar. 2005
[3]
3.6.3
Replacing the Imaging Unit (C, M, Y, K)
3. Hold the handle and install the
Waste Toner Box [3] in position.
4. Close the Left Door.
5. Close the Right Door.
NOTE
• Make sure that the door is locked in
position both at front and rear.
6. Turn ON the Main Power Switch.
7. Select "Service Mode" → "Imaging
Process Adjustment" → "Gradation
Adjust" and carry out Gradation
Adjust.
4037F2C529DA
A. Removal Procedure
1. Turn OFF the Main Power Switch.
2. Unplug the power cord.
3. Open the Front Door.
4. Release the lock lever [1] of the
[1]
Imaging Unit.
4036fs2578c0
5. Pull out the IU [2], and remove it from
main body.
6. Clean the LPH Assy.
☞ 26
[2]
4036fs2579c0
3. Periodical check
31