3. Periodical check
3.4.10
Replacing the paper feed tray 1 separation roller assy
A. Periodically replacing parts/cycle
• Paper feed tray 1 separation roller assy: Every 200,000 prints
B. Procedure
1. Remove the paper feed tray 1 unit.
See P.83
[2]
[1]
[1]
[2]
28
Confidential – for internal use only, do not distribute
A02EF2C023DA
A02EF2C024DA
[1]
[2]
A02EF2C025DA
Field Service Ver. 2.0 Nov. 2007
2. Remove two springs [1] and the
guide plate [2].
3. Remove the screw [1], and remove
the ground terminal [2].
4. Remove the screw [1], and remove
the paper feed tray 1 separation
roller assy [2].