7. Trouble code
7.3.5
C0213: LCT shift gate operation failure
Division board position sensor (PS14)
Division board position motor (M3)
Step
Check the motor and sensor connectors for
1
proper connection, and correct as neces-
sary.
Check the connector of motor for proper
2
drive coupling, and correct as necessary.
3
PS14 I/O check
4
M3 operation check
5
PCCB replacement
7.3.6
C0214: LCT shift failure
Shift motor pulse sensor (PS8)
Shift tray stop sensor (PS11)
Shift tray home sensor (PS12)
Step
Check the sensor connectors for proper
1
connection, and correct as necessary.
2
PS8 I/O check
3
PS11 I/O check
4
PS12 I/O check
5
PCCB replacement
36
Confidential – for internal use only, do not distribute
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.0 Oct. 2007
PC control board (PCCB)
WIRING DIAGRAM
Control signal
—
—
REYB PJ2REYB<B>-1 (ON)
REYB PJ2REYB<B>-2 to 3
—
PC control board (PCCB)
WIRING DIAGRAM
Control signal
—
REYB PJ2REYB<A>-3 (ON)
REYB PJ2REYB<A>-7 (ON)
REYB PJ2REYB<A>-8 (ON)
—
Location
(Electrical
components)
—
—
PC-406 K-7
PC-406 K-7
—
Location
(Electrical
components)
—
PC-406 K-6
PC-406 K-4
PC-406 K-4
—