Field Service Ver. 2.0 Nov. 2007
11. Procedure for resetting
11.1 Trouble resetting
Functions
• If the all troubles occur and the status would not be cleared by turning power switch
OFF and ON again, or opening and closing the front door, clear the status of the
machine.
Use
• To be used when the status would not be cleared by turning power switch OFF and
ON again, or opening and closing the front door in case of a trouble.
Setting/
1. Turn OFF the power switch.
Procedure
2. Turn power switch ON while pressing the Menu/Select key.
3. Check that the Trouble Reset screen appears.
4. Press the Menu/Select key.
5. Check to make sure that [Completed. Please turn power OFF and ON.] is displayed
and the it has been reset.
6. After turning off the power switch, turn it on again more than 10 seconds after and
check if the machine starts correctly.
11.2 Contents to be cleared by reset function
Items for clearing
Contents to be cleared
Jam display
Rank A Fusing
Malfunction
Rank B
display
Rank C
Erratic operation / display
Utility Mode
(Except items on
Expert Adjustment.)
Counter Setting
Billing Setting
Management
Function Choice
: Will be cleared (initialized)
-: Will not be cleared
Confidential – for internal use only, do not distribute
Power
Front door
switch
open/close
OFF/ON
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
11. Procedure for resetting
Initialization
Trouble
System
resetting
Error Clear
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
Data Clear
⎯
⎯
⎯
⎯