"3: CODABAR": Detail setting of the Codabar (NW-7) reading
1.
Select "3: CODABAR" at the SET BARCODE menu and then press the ENT key.
The SET CODABAR screen appears.
"1: MIN":
Sets the minimum number of the Codabar digits.
Setting range:
"2: MAX":
Sets the maximum number of the Codabar digits.
Setting range:
Always set the minimum number of digits to a number less than the maximum number of
− Point −
digits. If the minimum number exceeds the maximum number, a read error occurs
"3: START CODE":
"4: STOP CODE":
Sets the start and stop codes to "?, A, B, C, D".
If "A, B, C, D" is specified, barcode reading is limited for the Codabar; the barcode for which the start
and stop codes are the same as the specified characters is only read. If "?" is specified, no limitation
is carried out.
"5: CD CHECK":
"ON":
"OFF":
2.
Use the cursor keys ([▲] [▼]) or numeric keys ([1] [2] [3] [4] [5]) to select the desired item.
3.
Press the cursor keys ([◄] [►]) to select the desired setting.
4.
Press the ENT or Backspace/clear key to update the setting and return to the SET BARCODE
menu.
76
3 to 99
3 to 99
Reading is carried out only if the check digit is correct. Reading is not carried out if either
the check digit is incorrect or does not exit.
Reading is carried out regardless of the presence of the check digit.