Proxy Server Issues; Troubleshooting Alert And Trap Problems; Inability To Receive Insight Manager 7 Or Systems Insight Manager Alarms (Snmp Traps) From Ilo - HP Integrated Lights-Out User Manual

Hp integrated lights-out user guide
Hide thumbs Also See for HP Integrated Lights-Out:
Table of Contents

Advertisement

Proxy Server Issues

If the Web browser software is configured to use a proxy server, it will not
connect to the iLO IP address. To resolve this issue, configure the browser not to
use the proxy server for the IP address of iLO. For example, in Internet Explorer,
select Tools, Internet Options, Connections, LAN Settings, Advanced, and
then enter the iLO IP address or DNS name in the Exceptions field.

Troubleshooting Alert and Trap Problems

Alert
Test Trap
Server Power Outage
Server Reset
Failed Login Attempt
General Error
Logs
Security Override Switch
Changed: On/Off
Rack Server Power On
Failed
Rack Server Power On
Manual Override
Rack Name Changed
Inability to Receive Insight Manager 7 or Systems Insight
Manager Alarms (SNMP Traps) from iLO
A user with the Configure iLO Settings privilege must connect to iLO to
configure SNMP trap parameters. When connected to iLO, be sure that the
correct alert types and trap destinations are enabled in the SNMP/Insight
Manager Settings screen of the iLO console application.
Explanation
This trap is generated by a user through the Web configuration page.
Server has lost power.
Server has been reset.
Remote user login attempt failed.
This is an error condition that is not predefined by the hard-coded MIB.
Circular log has been overrun.
The state of the Security Override Switch has changed (On/Off).
The server was unable to power on because the BL p-Class rack
indicated that insufficient power was available to power on the server.
The server was manually forced by the customer to power on despite
the BL p-Class reporting insufficient power.
The name of the ProLiant BL p-Class rack was changed.
Troubleshooting iLO