HP Integrated Lights-Out User Manual page 97

Hp integrated lights-out user guide
Hide thumbs Also See for HP Integrated Lights-Out:
Table of Contents

Advertisement

2. Select SNMP/Insight Manager Settings in the
3. Enter up to three IP addresses to receive the SNMP alerts.
4. Select the alert options you want iLO to support. For information on the
5. Click Apply Settings.
Generating Test Alerts
Test alerts are generated by means of the SNMP/Insight Manager Settings in the
Administration section of the iLO navigation frame. These alerts include an
Insight Manager SNMP trap and are used to verify the network connectivity of
iLO in Insight Manager 7 and Systems Insight Manager. Only users with the
Configure iLO Settings privilege can send test alerts.
Click Apply Settings to save any changes made to SNMP Alert Destination(s)
before sending a test alert.
Administration tab.
Forward Insight Manager Agent SNMP Alerts field.
Using iLO
97