RESET_SERVER_PRIV is a Boolean parameter that gives the user permission
to remotely manipulate the server power setting. This parameter is optional, and
the Boolean string must be set to "Yes" if the user should have this privilege. If
this parameter is used, the Boolean string value must never be left blank.
Omitting this parameter prevents the user from manipulating the server power
settings.
VIRTUAL_MEDIA_PRIV is a Boolean parameter that gives the user permission
to access the virtual media functionality. This parameter is optional, and the
Boolean string must be set to "Yes" if the user should have this privilege. If this
parameter is used, the Boolean string value must never be left blank. Omitting
this parameter denies the user virtual media privileges.
CONFIG_ILO_PRIV is a Boolean parameter that allows the user to configure
iLO settings. This privilege includes network settings, global settings, Insight
Manager settings, and SNMP settings. This parameter is optional, and the
Boolean string must be set to "Yes" if the user should have this privilege. If this
parameter is used, the Boolean string value must never be blank. Omitting this
parameter prevents the user from manipulating the current iLO configuration.

MOD_USER Runtime Errors

The possible MOD_USER error messages include:
Login name is too long.
Password is too short.
Password is too long.
User information is open for read-only access. Write access is required for
this operation.
User login name must not be blank.
Cannot modify user information for currently logged user.
User does not have correct privilege for action. ADMIN_PRIV required.